resources:cd101 [01/25/2011 07:05] – [Photos] jeffresources:cd101 [02/23/2011 06:13] (current) davidpincus
Line 31: Line 31:
 These settings can be accessed by holding SET and < at the same time for 3s, then setting Cod to 0000.  More information is available in the 2nd user manual given above. These settings can be accessed by holding SET and < at the same time for 3s, then setting Cod to 0000.  More information is available in the 2nd user manual given above.
   * SL 1 sets the input type, defaults is K-type thermocouple.  Chart in 2nd manual listed above.   * SL 1 sets the input type, defaults is K-type thermocouple.  Chart in 2nd manual listed above.
-    * I haven't verified that other inputs actually function correctly, but Scott's Sous Vide cooker uses a PT100 sensor and it apparently works.+    * I haven't verified that other inputs actually function correctly, but Scott's Sous Vide cooker uses a PT100 sensor and it apparently works. UPDATE: SL1=1100 setting for PT100 changes the display to include one decimal point. //David 23/02/2011 //
   * SL 2 = 0000 sets the unit to display all temperatures in Celsius   * SL 2 = 0000 sets the unit to display all temperatures in Celsius
   * SL 2 = 0001 sets the unit to display all temperatures in Fahrenheit   * SL 2 = 0001 sets the unit to display all temperatures in Fahrenheit
   * SL 6 = 0001 disables OUT2 (the relay output) and stops the audible clicking associated with it   * SL 6 = 0001 disables OUT2 (the relay output) and stops the audible clicking associated with it
 +  * SL10 = 0001 enable STOP mode (which doesn't appear to work correctly anyway)
 +  * SL10 = 1000 enable ST (Self Tune) mode - makes ST appear in the menus
  
  