====== CD101 PID Controller ====== | ====== CD101 PID Controller ====== | ||
- | * | + | |
- | * [[http:// | + | Cheap ($33 USD), K-type thermocouple (apparently this can be changed in the " |
- | * [[http:// | + | |
+ | Available from [[http:// | ||
+ | |||
+ | The unit I received has two control outputs, SSR (OUT1) and RELAY (OUT2) and is labeled: | ||
+ | |||
+ | |CODE |FK02-VM*AN-NN\\ ZK-1018| | ||
+ | |RANGE | ||
+ | |INPUT | ||
+ | |OUTPUT |SSR RELAY| | ||
+ | |||
+ | Examples of this controller in use: | ||
+ | |||
+ | * Keith used this one in his [[http:// | ||
+ | * Make: volume 25 includes a [[http:// | ||
+ | * The Make article is based on [[http:// | ||
+ | |||
+ | ===== User Manuals ===== | ||
+ | |||
+ | * [[http:// | ||
+ | * [[http:// | ||
+ | * This includes information about the "meter parameter mode" or " | ||
+ | |||
+ | ===== Undocumented Settings / Features ===== | ||
+ | The available documentation for this controller is poor. By playing with the configuration settings, I have discovered some useful but undocumented features. | ||
+ | |||
+ | Note: These settings apply to the FK02-VM*AN-NN. | ||
+ | |||
+ | These settings can be accessed by holding SET and < at the same time for 3s, then setting Cod to 0000. More information is available in the 2nd user manual given above. | ||
+ | * SL 1 sets the input type, defaults is K-type thermocouple. | ||
+ | * I haven' | ||
+ | * SL 2 = 0000 sets the unit to display all temperatures in Celsius | ||
+ | * SL 2 = 0001 sets the unit to display all temperatures in Fahrenheit | ||
+ | * SL 6 = 0001 disables OUT2 (the relay output) and stops the audible clicking associated with it | ||
+ | * SL10 = 0001 enable STOP mode (which doesn' | ||
+ | * SL10 = 1000 enable ST (Self Tune) mode - makes ST appear in the menus | ||
+ | |||
+ | |||
+ | ===== Known Issues ===== | ||
+ | * The STOP feature doesn' | ||
+ | * Pressing the R/S button for 2 sec results in STOP being shown on the upper display, but the outputs continue to function. | ||
+ | |||
+ | ===== Photos ===== | ||
+ | Photos of CD101 disassembly thanks to [[http:// | ||
+ | |||
+ | {{: | ||
+ | {{: | ||
+ | {{: | ||
+ | {{: | ||
+ | {{: |
resources/cd101.txt · Last modified: 02/23/2011 06:13 by davidpincus