| ====== CD101 PID Controller ====== | ====== CD101 PID Controller ====== | ||
| - | * | + | Cheap ($33 USD), K-type thermocouple (apparently this can be changed in the " |
| + | |||
| + | Available from [[http:// | ||
| + | |||
| + | The unit I received has two control outputs, SSR (OUT1) and RELAY (OUT2) and is labeled: | ||
| + | |||
| + | |CODE |FK02-VM*AN-NN\\ ZK-1018| | ||
| + | |RANGE | ||
| + | |INPUT | ||
| + | |OUTPUT |SSR RELAY| | ||
| + | |||
| + | Examples of this controller in use: | ||
| + | |||
| + | * Keith used this one in his [[http:// | ||
| * Make: volume 25 includes a [[http:// | * Make: volume 25 includes a [[http:// | ||
| * The Make article is based on [[http:// | * The Make article is based on [[http:// | ||
| Line 9: | Line 22: | ||
| * [[http:// | * [[http:// | ||
| * [[http:// | * [[http:// | ||
| + | * This includes information about the "meter parameter mode" or " | ||
| ===== Undocumented Settings / Features ===== | ===== Undocumented Settings / Features ===== | ||
| Line 16: | Line 30: | ||
| These settings can be accessed by holding SET and < at the same time for 3s, then setting Cod to 0000. More information is available in the 2nd user manual given above. | These settings can be accessed by holding SET and < at the same time for 3s, then setting Cod to 0000. More information is available in the 2nd user manual given above. | ||
| + | * SL 1 sets the input type, defaults is K-type thermocouple. | ||
| + | * I haven' | ||
| * SL 2 = 0000 sets the unit to display all temperatures in Celsius | * SL 2 = 0000 sets the unit to display all temperatures in Celsius | ||
| * SL 2 = 0001 sets the unit to display all temperatures in Fahrenheit | * SL 2 = 0001 sets the unit to display all temperatures in Fahrenheit | ||
| * SL 6 = 0001 disables OUT2 (the relay output) and stops the audible clicking associated with it | * SL 6 = 0001 disables OUT2 (the relay output) and stops the audible clicking associated with it | ||
| + | * SL10 = 0001 enable STOP mode (which doesn' | ||
| + | * SL10 = 1000 enable ST (Self Tune) mode - makes ST appear in the menus | ||
| Line 25: | Line 43: | ||
| * Pressing the R/S button for 2 sec results in STOP being shown on the upper display, but the outputs continue to function. | * Pressing the R/S button for 2 sec results in STOP being shown on the upper display, but the outputs continue to function. | ||
| + | ===== Photos ===== | ||
| + | Photos of CD101 disassembly thanks to [[http:// | ||
| + | {{: | ||
| + | {{: | ||
| + | {{: | ||
| + | {{: | ||
| + | {{: | ||